SATEC RPT091 MODBUS ÇÁ·ÎÅäÄÝÀÇ Àбâ/¾²±â Á¾·ùº° ÀúÀå³»¿ë°ú Ãâ·Â¹øÁö

 

SATEC RPT091 µå¶óÀ̺êÀÇ Åë½Å ÇÁ·ÎÅäÄÝÀ» MODBUS·Î ¼±ÅÃ( PROT ´ÜÀÚ¸¦ Close )ÇßÀ» ¶§ÀÇ Àбâ/¾²±â Á¾·ùº° ¸Þ¸ð¸®¿¡ ÀúÀåµÈ ³»¿ë°ú ÀúÀåÀ§Ä¡´Â ´ÙÀ½°ú °°´Ù.

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡,
Ãâ·Â¹øÁö
³»   ¿ë ´Ü À§ ¹ü À§ modbus address ¾²±â
ÀúÀåÀ§Ä¡ + 0 ~ 2 L1~L3/L12 ~ L31 Àü¾Ð V 0 ~ Vmax 256 ~ 258 -
ÀúÀåÀ§Ä¡ + 3 ~ 5 L1 ~ L3 Àü·ù A 0 ~ Imax 259 ~ 261
ÀúÀåÀ§Ä¡ + 6 ~ 8 L1 ~ L3 Àü·Â(KW) KW -Pmax ~ Pmax 262 ~ 264
ÀúÀåÀ§Ä¡ + 9 ~ 11 L1 ~ L3 Kvar Kvar 265 ~ 267
ÀúÀåÀ§Ä¡ +12 ~ 14 L1 ~ L3 KVA KVA 268 ~ 270
ÀúÀåÀ§Ä¡ +15 ~ 17 L1 ~ L3 Power Factor - -1 ~ 1 271 ~ 273
ÀúÀåÀ§Ä¡ +18 Power Factor Total 274
ÀúÀåÀ§Ä¡ +19 KW Total KW -Pmax ~ Pmax 275
ÀúÀåÀ§Ä¡ +20 Kvar Total Kvar 276
ÀúÀåÀ§Ä¡ +21 KVA Total KVA 277
ÀúÀåÀ§Ä¡ +22 Unbalanced Àü·ù A 0 ~ Imax 278
ÀúÀåÀ§Ä¡ +23 ÁÖÆļö HZ 45 ~ 65 279
ÀúÀåÀ§Ä¡ +24 Sliding window maximum KW demand KW -Pmax ~ Pmax 280 °¡´É
ÀúÀåÀ§Ä¡ +25 Accumulated KW demand 281
ÀúÀåÀ§Ä¡ +26 Sliding window maximum KVA demand KVA 282
ÀúÀåÀ§Ä¡ +27 Accumulated KVA demand 283
ÀúÀåÀ§Ä¡ +28 ~ 30 Maximum Àü·ù demand L1 ~ L3 A 0 ~ Imax 284 ~ 286
ÀúÀåÀ§Ä¡ +31 ~ 32 KWh Import Low/High Word KWh 0 ~ 9999 287 ~ 288
ÀúÀåÀ§Ä¡ +33 KWh Export Low Word 289
ÀúÀåÀ§Ä¡ +34 KWh Export High Word 0 ~ 999 290
ÀúÀåÀ§Ä¡ +35 ~ 36 Kvarh Import Low/High Word Kvarh 0 ~ 9999 291 ~ 292
ÀúÀåÀ§Ä¡ +37 ~ 38 Kvarh Export Low/High Word 293 ~ 294
ÀúÀåÀ§Ä¡ +39 ~ 41 L1~L3/L12 ~ L31 THD Àü¾Ð % 0 ~ 999.9 295 ~ 397 -
ÀúÀåÀ§Ä¡ +42 ~ 44 L1~L3 THD Àü·ù 398 ~ 300
ÀúÀåÀ§Ä¡ +45 ~ 46 KVAh Low/High Word KVAh 0 ~ 9999 301 ~ 302 °¡´É
ÀúÀåÀ§Ä¡ +47 Sliding window KW demand KW -Pmax ~ Pmax 303 -
ÀúÀåÀ§Ä¡ +48 Sliding window KVA demand KVA 304
ÀúÀåÀ§Ä¡ +49 Reserved (»ç¿ë¾ÈÇÔ) - - 305
ÀúÀåÀ§Ä¡ +50 ~ 52 L1 ~ L3 TDD Àü·ù % 0 ~ 100 306 ~ 308

<Ç¥ 1> DATA Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡,
Ãâ·Â¹øÁö
³»     ¿ë ´Ü À§

¹ü À§

modbus address ¾²±â
ÀúÀåÀ§Ä¡ + 0 Wiring mode -

0 ~ 6,

(0 = 3OP2,

1 = 4LN3,

2 = 3DIR2,

3 = 4LL3,

4 = 3OP3,

5 = 3LN3,

6 = 3LL3)

2304 °¡´É
ÀúÀåÀ§Ä¡ + 1 PT Ratio

1.0 ~ 6500.0

2305
ÀúÀåÀ§Ä¡ + 2 CT Primary Àü·ù A

1 ~ 50000

2306
ÀúÀåÀ§Ä¡ + 3 Demand °£°Ý min

1, 2, 5, 10, 15, 20, 30, 60,

255 = ¿ÜºÎ Sync

2307
ÀúÀåÀ§Ä¡ + 4 Ampere Demand °£°Ý sec

0 ~ 1800

2308
ÀúÀåÀ§Ä¡ + 5 Æò±Õ ¹öÆÛ Å©±â -

8, 16, 32

2309
ÀúÀåÀ§Ä¡ + 6 Reset Enable/Disable

0 = Disable,

1 = Enable

2310
ÀúÀåÀ§Ä¡ + 7 Reserved

Ç×»ó 65535

2311 -
ÀúÀåÀ§Ä¡ + 8 Demand periods No

1 ~ 15

2312 °¡´É
ÀúÀåÀ§Ä¡ + 9 ~ 10 Reserved

Ç×»ó 65535

2313 ~ 2314 -
ÀúÀåÀ§Ä¡ + 11 ±âº» ÁÖÆļö HZ

50, 60

2315 °¡´É
ÀúÀåÀ§Ä¡ + 12 ÃÖ´ë Demand Load Àü·ù A

1 ~ 50000

2316
ÀúÀåÀ§Ä¡ + 13 Phase Energy Mode -

 0 = Disable,

1 = Enable

2317

<Ç¥ 2> SETUP Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡,Ãâ·Â¹øÁö

³»     ¿ë

¹ü À§

modbus address ¾²±â
ÀúÀåÀ§Ä¡ + 0

Instrument reset register

0 = Àбâ,

65535 = ¾²±â(Warm reset)

2560 °¡´É
ÀúÀåÀ§Ä¡ + 1

Reserved

Ç×»ó 0

2561 -
ÀúÀåÀ§Ä¡ + 2

Relay »óÅÂ

0 ~ 5  Bit : Ç×»ó 1,

6      Bit : Relay 2 »óÅÂ,

7      Bit : Relay 1 »óÅÂ,

8 ~ 15 Bit : Ç×»ó 0,

 

* Relay »óÅÂ

0 = Operated,

1 = Released

2562
ÀúÀåÀ§Ä¡ + 3

Reserved

Ç×»ó 0

2563
ÀúÀåÀ§Ä¡ + 4

Status Inputs

0~3Bit : Status Input 1~4,

4~15Bit : Ç×»ó 0

 

* Relay »óÅÂ

0 = Open,

1 = Close

2564
ÀúÀåÀ§Ä¡ + 5

Firmware version ¹øÈ£

0 ~ 65535

2565
ÀúÀåÀ§Ä¡ + 6

Instrument Option 1

0  Bit : 120V Option,

1  Bit : 690V Option,

2 ~ 4  Bit : Reserved,

5  Bit : 50% Àü·ù over range option,

6  Bit : Analog Output 0/4 ~ 20mA Option,

7  Bit : Analog Output 0 ~ 1mA Option,

8  Bit : Analog Output -1 ~ +1mA Option,

9  Bit : Relays Option,

10 Bit : Digital Inputs Option,

11 ~ 15 Bit : Reserved

2566
ÀúÀåÀ§Ä¡ + 7

Instrument Option 2

0 ~ 1 Bit : Number of Relays - 1,

2 ~ 6 Bit : Number of Digital Inputs - 1,

7 ~ 15  Bit : Reserved,

2567

<Ç¥ 3> STATUS Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ ³»     ¿ë

¹ü À§

modbus address

ÀúÀåÀ§Ä¡ + 0 Firmware version ¹øÈ£

0 ~ 65535

2349

ÀúÀåÀ§Ä¡ + 1 Instrument Option 1

0  Bit : 120V Option,

1  Bit : 690V Option,

2 ~ 4  Bit : Reserved,

5  Bit : 50% Àü·ù over range option,

6  Bit : Analog Output 0/4 ~ 20mA Option,

7  Bit : Analog Output 0 ~ 1mA Option,

8  Bit : Analog Output -1 ~ +1mA Option,

9  Bit : Relays Option,

10 Bit : Digital Inputs Option,

11 ~ 15 Bit : Reserved

2350

ÀúÀåÀ§Ä¡ + 2 Instrument Option 2

0 ~ 1 Bit : Number of Relays - 1,

2 ~ 6 Bit : Number of Digital Inputs - 1,

7 ~ 15  Bit : Reserved,

2351

<Ç¥ 4> VER ÀÐÀ» Á¾·ùÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (Àб⸸ °¡´É)

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±âAddress ³»     ¿ë ¹ü À§ modbus address
ÀúÀåÀ§Ä¡ + 0 0 1¹ø AO allocation register parameter ID 0 ~ 5649
( <Ç¥ 6> ÂüÁ¶ )
3148
ÀúÀåÀ§Ä¡ + 1 1 1¹ø AO zero scale (0/4 mA) <Ç¥ 6> ÂüÁ¶ 3149
ÀúÀåÀ§Ä¡ + 2 2 1¹ø AO full scale (20/1 mA) 3150
ÀúÀåÀ§Ä¡ + 3 ~ 5 3 ~ 5 2¹ø AO ÀÇ ID, zero/full scale 3151 ~ 3153
ÀúÀåÀ§Ä¡ + 6 ~ 8 6 ~ 8 3¹ø AO ÀÇ ID, zero/full scale 3154 ~ 3156
ÀúÀåÀ§Ä¡ + 9 ~ 44 9 ~ 44 4 ~ 15¹ø AO ÀÇ ID, zero/full scale 3157 ~ 3192
ÀúÀåÀ§Ä¡ + 45 ~ 47 45 ~ 47 16¹ø AO ÀÇ ID, zero/full scale 3193 ~ 3195

<Ç¥ 5> AO Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

ID ¹øÈ£ ³»     ¿ë ¹ü À§ ´Ü À§
0 ¾øÀ½ 0 -
3072 ~ 3074 L1/L12 ~ L3/L31 Àü¾Ð ÇöÀç °ª 0 ~ Vmax V
3075 ~ 3077 L1 ~ L3 Àü·ù ÇöÀç °ª 0 ~ Imax A
3840 Total KW ÇöÀç °ª -Pmax ~ Pmax KW
3841 Total Kvar ÇöÀç °ª Kvar
3842 Total KVA ÇöÀç °ª 0 ~ Pmax KVA
3843 Total PF ÇöÀç °ª -1 ~ 1 -
3844 Total PF lag ÇöÀç °ª 0 ~ 1
3845 Total PF lead ÇöÀç °ª
4098 ÁÖÆļö 0 ~ 100.0 HZ
4352 ~ 5354 L1/L12 ~ L3/L31 Æò±Õ Àü¾Ð 0 ~ Vmax V
4355 ~ 4357 L1 ~ L3 Æò±Õ Àü·ù 0 ~ Imax A
5120 Total KW Æò±Õ °ª -Pmax ~ Pmax KW
5121 Total Kvar Æò±Õ °ª Kvar
5122 Total KVA Æò±Õ °ª 0 ~ Pmax KVA
5123 Total PF Æò±Õ °ª -1 ~ 1 -
5124 Total PF lag Æò±Õ °ª 0 ~ 1
5125 Total PF lead Æò±Õ °ª
5377 Neutral Æò±Õ Àü·ù 0 ~ Imax A
5378 Æò±Õ ÁÖÆļö 0 ~ 100.0 HZ
5647 Accumulated KW demand 0 ~ Pmax KW
5649 Accumulated KVA demand KVA

<Ç¥ 6> Analog Output Parameter ID ¹øÈ£ ¹× ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±âAddress ³»     ¿ë ¹ü À§ modbus address
ÀúÀåÀ§Ä¡ + 0 0 1¹ø ACH allocation register parameter ID 0 ~ 5649
( <Ç¥ 6> ÂüÁ¶ )
3196
ÀúÀåÀ§Ä¡ + 1 1 1¹ø ACH zero scale (0/4 mA) <Ç¥ 6> ÂüÁ¶ 3197
ÀúÀåÀ§Ä¡ + 2 2 1¹ø ACH full scale (20 mA) 3198
ÀúÀåÀ§Ä¡ + 3 ~ 5 3 ~ 5 2¹ø ACH ÀÇ ID, zero/full scale 3199 ~ 3201
ÀúÀåÀ§Ä¡ + 6 ~ 8 6 ~ 8 3¹ø ACH ÀÇ ID, zero/full scale 3202 ~ 3204
ÀúÀåÀ§Ä¡ + 9 ~ 38 9 ~ 38 4 ~ 13¹ø ACH ÀÇ ID, zero/full scale 3205 ~ 3234
ÀúÀåÀ§Ä¡ + 39 ~ 41 39 ~ 41 14¹ø ACH ÀÇ ID, zero/full scale 3235 ~ 3237

<Ç¥ 7> ACH Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡,
Ãâ·Â¹øÁö
³»     ¿ë

Bit º° ³»¿ë

modbus address

¾²±â

ÀúÀåÀ§Ä¡ + 0 Status Input allocation

0 ~ 3 bit  = 

DI 1 ~ 4 allocation status,

(0 : not allocated,

1 : allocated to the group)

4 ~ 15 bit = »ç¿ë¾ÈÇÔ ( 0 )

3292

-

ÀúÀåÀ§Ä¡ + 1 Pulse Input allocation

3293

ÀúÀåÀ§Ä¡ + 2 AO multiplexer allocation

3294

°¡´É

ÀúÀåÀ§Ä¡ + 3 External synchronization allocation

3295

<Ç¥ 8> DI Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±âAddress ³»     ¿ë

¹ü À§

modbus address

ÀúÀåÀ§Ä¡ + 0 0 1¹ø Relay Control »óÅÂ

0 = Normal Operation,

1 = Force Operate,

2 = Force Release.

3244

ÀúÀåÀ§Ä¡ + 1 1 2¹ø Relay Control »óÅÂ

3245

<Ç¥ 9> RELAY Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±âAddress ³»     ¿ë

¹ü À§

modbus address
ÀúÀåÀ§Ä¡ + 0 0 Relay 1¹ø Pulsing
setpoint Parameter ID

0 ~ 7

(0 = none,

1 = KWh import,

2 = KWh export,

4 = Kvarh import(inductive),

5 = Kvarh export(capacitive),

6 = Kvarh total,

7 = KVA total)

2892
ÀúÀåÀ§Ä¡ + 1 1 Relay 1¹ø Pulsing
setpoint ´ÜÀ§½Ã°£ ´ç Pulse ¼ö

Energy pulsing  = 1 ~ 9999

±âŸ = 0.

2893
ÀúÀåÀ§Ä¡ + 2 ~ 3 2 ~ 3 Relay 2¹ø Parameter ID,
´ÜÀ§½Ã°£ ´ç Pulse ¼ö

Relay 1¹ø °ú µ¿ÀÏ

2894 ~2895

<Ç¥ 10> PULSE Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±âAddress ³»     ¿ë ¹ü À§ modbus address
ÀúÀåÀ§Ä¡ + 0 0 ÇöÀç½Ã°£ Sec (ÃÊ) 0 ~ 59 4352
ÀúÀåÀ§Ä¡ + 1 1 ÇöÀç½Ã°£ Min (ºÐ) 0 ~ 59 4353
ÀúÀåÀ§Ä¡ + 2 2 ÇöÀç½Ã°£ Hour (½Ã) 0 ~ 23 4354
ÀúÀåÀ§Ä¡ + 3 3 ÇöÀ糯¥  Day (ÀÏ) 1 ~ 31 4355
ÀúÀåÀ§Ä¡ + 4 4 ÇöÀ糯¥  Month (¿ù) 1 ~ 12 4356
ÀúÀåÀ§Ä¡ + 5 5 ÇöÀ糯¥  Year (³â) 0 ~ 99 4357
ÀúÀåÀ§Ä¡ + 6 6 ÇöÀ糯¥ Week (¿äÀÏ) 1 ~ 7 (1 = Sunday, ¡¦) 4358

<Ç¥ 11> RTC Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±âAddress ³»     ¿ë ¹ü À§ modbus address
ÀúÀåÀ§Ä¡ + 0 ~ 119 0 ~ 119 User-Define
Register 0 ~ 119
240 ~ 9999
(modbus address)
120 ~ 239

<Ç¥ 12> DEFINE Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡,
Ãâ·Â¹øÁö
³»     ¿ë ¹ü À§ modbus address ¾²±â
ÀúÀåÀ§Ä¡ + 0 ~ 119 User-Definable Data 0 ~ 119 Mapping µÈ(<Ç¥ 12>) Register ¹øÈ£(modbus address)¿¡ µû¶ó ¡¦ 0 ~ 119 MapµÈ ¹øÁö¿¡ µû¶ó ..

<Ç¥ 13> MAP Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸®
ÀúÀåÀ§Ä¡
Àбâ/¾²±âAddress

³»     ¿ë

¹ü À§

modbus address
ÀúÀåÀ§Ä¡ + 0 0 1¹ø Alarm setpoint Trigger Parameter ID

0 ~ 37893

(<Ç¥ 15> ÂüÁ¶)

2576
ÀúÀåÀ§Ä¡ + 1 1 1¹ø Alarm setpoint Action

0 = No Action,

12288 = Operate Relay 1,

12289 = Operate Relay 2

2577
ÀúÀåÀ§Ä¡ + 2 ~ 3 2 ~ 3 1¹ø Alarm setpoint Operate,
Release Delay

0 ~ 9999 (x 0.1 ÃÊ)

2578 ~ 2579
ÀúÀåÀ§Ä¡ + 4 ~ 5 4 ~ 5 1¹ø Alarm setpoint Operate limit Low/High WORD

Parameter ID ¿¡ µû¶ó¡¦

(<Ç¥ 15> ÂüÁ¶)

2580 ~ 2581
ÀúÀåÀ§Ä¡ + 6 ~ 7 6 ~ 7 1¹ø Alarm setpoint Release limit Low/High WORD

Parameter ID ¿¡ µû¶ó¡¦

(<Ç¥ 15> ÂüÁ¶)

2582 ~ 2583
ÀúÀåÀ§Ä¡ + 8 ~ 15 8 ~ 15 2¹ø Alarm setpoint ID, Action, Delay, Limit

1¹ø Alarm Setpoint ¿Í µ¿ÀÏ

2584 ~ 2591
ÀúÀåÀ§Ä¡ + 16 ~ 119 16 ~ 119 3 ~15¹ø Alarm setpoint ID, Action, Delay, Limit 2585 ~ 2695
ÀúÀåÀ§Ä¡ + 120 ~ 127 120 ~ 127 16¹ø Alarm setpoint ID, Action, Delay, Limit 2696 ~ 2703

<Ç¥ 14> ALARM Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

Alarm Trigger Parameter ID ³»     ¿ë ¹ü À§ ´Ü À§
0 »ç¿ë¾ÈÇÔ - -
1536 ~ 1539 Status Input 1 ~ 4 ON
34304 ~ 34307 Status Input 1 ~ 4 OFF
35073 Positive phase rotation Reversal
35074 Negative phase rotation Reversal
3075 ~ 3077 High Àü·ù L1 ~ L3 ÇöÀç °ª 0 ~ Imax A
35843 ~ 35845 Low Àü·ù L1 ~ L3 ÇöÀç °ª
3584 High Àü¾Ð ÇöÀç °ª 0 ~ Vmax V
36096 Low Àü¾Ð ÇöÀç °ª
3591 ~ 3592 High Àü¾Ð/Àü·ù THD 0 ~ 999.9 %
3594 High  Àü·ù TDD 0 ~ 100.0
4098 High ÁÖÆļö 0 ~ 100.0 HZ
36866 Low ÁÖÆļö
4355 ~ 4357 High Àü·ù L1 ~ L3 Æò±Õ °ª 0 ~ Imax A
37123 ~ 37125 Low Àü·ù L1 ~ L3 Æò±Õ °ª
4864 High Àü¾Ð Æò±Õ °ª 0 ~ Vmax V
37376 Low Àü¾Ð Æò±Õ °ª
5126 ~ 5127 High total KW import, export 0~ Pmax KW
5128 ~ 5129 High total Kvar import, export Kvar
5122 High total KVA KVA
37892 ~ 37893 Low total PF lag, lead 0 ~ 1 -
5377 High Neutral Àü·ù 0 ~ Imax A
5635 ~ 5637 High ampere demand L1 ~ L3
5638 High block KW demand 0 ~ Pmax KW
5640 High block KVA demand KVA
5641 High sliding window KW demand KW
5643 High sliding window KVA demand KVA
5647 High accumulated KW demand KW
5649 High accumulated KVA demand KVA

<Ç¥ 15> ALARM Àбâ, ¾²±âÀÇ Trigger Parameter ID¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡,
Ãâ·Â¹øÁö
³»     ¿ë

¹ü À§

modbus address

¾²±â

ÀúÀåÀ§Ä¡ + 0 Reserved

Ç×»ó 65535

2344

-

ÀúÀåÀ§Ä¡ + 1 Interface

1 = RS422,

2 = RS485

2345

°¡´É

ÀúÀåÀ§Ä¡ + 2 Address

0 ~ 247

2346

ÀúÀåÀ§Ä¡ + 3 Baud rate

0 = 110,

1 = 300,

2 = 600,

3 = 1200,

4 = 2400,

5 = 4800,

6 = 9600,

7 = 19200

2347

ÀúÀåÀ§Ä¡ + 4 Data format

0 = 7 data bits/even parity,

1 = 8 data bits/no parity,

2 = 8 data bits/even parity

2348

<Ç¥ 16> COMM Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡,
Ãâ·Â¹øÁö
³»     ¿ë

¹ü À§

modbus address ¾²±â
ÀúÀåÀ§Ä¡ + 0 Relay status

0 ~ 1bit = 1 ~ 2¹ø Relay status,

    (OFF : released, ON : Operate)

2bit ~ 15 bit = »ç¿ë¾ÈÇÔ.( Ç×»ó 0 )

3452 -
ÀúÀåÀ§Ä¡ + 1 Reserved

Ç×»ó 0

3453
ÀúÀåÀ§Ä¡ + 2 Status inputs

0 ~ 3bit = 1 ~ 4¹ø Status input,

    (OFF : Open, ON : Closed)

4bit ~ 15 bit = »ç¿ë¾ÈÇÔ.( Ç×»ó 0 )

3454
ÀúÀåÀ§Ä¡ + 3 Setpoints status

0 ~ 15bit = 1 ~ 16¹ø Setpoints status,

(OFF : released, ON : Operate)

3455
ÀúÀåÀ§Ä¡ + 4 ~ 21 Reserved

Ç×»ó 0

3456 ~ 3473
ÀúÀåÀ§Ä¡ + 22 Setpoints alarm status

0 ~ 15bit = 1 ~ 16¹ø Setpoints alarm status,

(OFF : released, ON : Operate)

3474 °¡´É
ÀúÀåÀ§Ä¡ + 23 Self-check alarm status

0 bit = Reserved,

1 bit = ROM error,

2 bit = RAM error,

3 bit = Watchdog timer reset,

4 bit = Sampling failure,

5 bit = Out of control trap,

6 bit = Reserved,

7 bit = Timing failure,

8 bit = Loss of power (power up),

9 bit = External reset (warm restart),

10bit = Configuration corrupted,

11bit = RTC time synchronization required,

12 ~ 15 bit = reserved

(OFF : released, ON : Operate)

3475

<Ç¥ 17> ESR Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±âAddress ³»     ¿ë

¹ü À§

modbus address
ÀúÀåÀ§Ä¡ + 0 0 Setpoints alarm status

0 ~ 15bit = 1 ~ 16¹ø Setpoints alarm status

(OFF : released, ON : Operate)

3474
ÀúÀåÀ§Ä¡ + 1 1 Self-check alarm status

0 bit = Reserved,

1 bit = ROM error,

2 bit = RAM error,

3 bit = Watchdog timer reset,

4 bit = Sampling failure,

5 bit = Out of control trap,

6 bit = Reserved,

7 bit = Timing failure,

8 bit = Loss of power (power up),

9 bit = External reset (warm restart),

10bit = Configuration corrupted,

11bit = RTC time synchronization required,

12 ~ 15 bit = reserved

(OFF : released, ON : Operate)

3475

<Ç¥ 18> ASR Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ ³»     ¿ë

¹ü À§

modbus address

ÀúÀåÀ§Ä¡ + 0 Instrument Option 1

0  Bit : 120V Option,

1  Bit : 690V Option,

2 ~ 4  Bit : Reserved,

5  Bit : 50% Àü·ù over range option,

6  Bit : Analog Output 0/4 ~ 20mA Option,

7  Bit : Analog Output 0 ~ 1mA Option,

8  Bit : Analog Output -1 ~ +1mA Option,

9  Bit : Relays Option,

10 Bit : Digital Inputs Option,

11 ~ 15 Bit : Reserved

2566

ÀúÀåÀ§Ä¡ + 1 Instrument Option 2

0 ~ 1 Bit : Number of Relays - 1,

2 ~ 6 Bit : Number of Digital Inputs - 1,

7 ~ 15  Bit : Reserved,

2567

<Ç¥ 19> OPTION ÀбâÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (Àб⸸ °¡´É)

 

 

* DIRECT – Long Size Direct Àбâ/¾²±â, VARIABLE – Variable Size Direct Àбâ/¾²±â´Â À§ÀÇ <Ç¥ 1> ~ <Ç¥ 19> modbus address Á÷Á¢ ¹øÁö¸¦ ÀÔ·ÂÇÏ¿© Àбâ/¾²±â¸¦ ¼öÇàÇÑ´Ù.

 

DIRECT ÀÐÀ» Á¾·ùÀÇ Àбâ´Â Ç×»ó 4 BYTE ( 2 WORD ) µ¥ÀÌÅ͸¦ Åë½Å ÇÁ·Î±×·¥(PLC_SCAN.EXE) ¸Þ¸ð¸®¿¡ º¸°üÇÏ°í VARIABLE Àбâ´Â ÀÐÀº ¸ðµç µ¥ÀÌÅ͸¦ 1BYTE ´ÜÀ§·Î Åë½Å ÇÁ·Î±×·¥(PLC_SCAN.EXE)ÀÇ ¸Þ¸ð¸®¿¡ º¸°üÇÑ´Ù.

¶ÇÇÑ modbus Åë½Å ÇÁ·ÎÅäÄÝÀÇ ¸ðµç ¾²±â´Â Çѹø¿¡ 2 BYTE( 1 WORD ) µ¥ÀÌÅ͸¦ Power Meter¿¡ Àü¼ÛÇÑ´Ù.